MKII DU-AL beams
Primary and secondary beams
Primary beams
The strongest primary beam in the range is the MkII Soldier, with a safe working load (SWL) bending of 38 kNm, making it ideal for falsework table use. Using MkII Soldiers, very large flying and rolling tables can be created without the need for splicing, as all the MkII Soldiers can be joined end to end. The lighter aluminium T225 DU-AL aluminium beam, with a SWL bending of 29 kNm, can be used when loading is less onerous and falsework structures require stripping and re-erecting.
Secondary beams
Two core secondary beams are available from our range. These are the single-web S150 DU-AL aluminium beam, with a SWL bending of 6.8 kNm, and the stronger twin-web T150 DU-AL aluminium beam, with SWL bending of 13 kNm. Both DU-AL aluminium secondary beams are supplied with a timber insert for suitable nailing of plywood.
Versatility
Timber wailings can also be clamped safely to MkII Soldiers, giving further choice in the selection of secondary beams to suit site requirements.
Application & use
Download the user guide here. Click on the name of a chapter to access it directly.
Overview of user guide
Technical data
Overall dimensions | T225: 10 x 22.5 cm | T150: 8.0 x 15 cm | S150: 7.5 x 15 cm |
Weight | T225: 8.92 kg/m | T150: 5.43 kg/m | S150: 3.24 kg/m |
Standard lengths | T225: 100 | 180 | 240 | 300 | 360 | 420 | 480 | 540 | 600 | 720 | 750 | 900 | 1000 cm T150: 100 | 120 | 130 | 160 | 180 | 250 | 360 | 390 | 420 | 480 | 500 | 540 | 600 | 640 | 720 cm S150: 100| 120 | 180 | 270 | 360 | 420 | 510 | 640 | 720 cm |
Moment of resistance | T225: 29.25 kNm | T150: 13.00 kNm | S150: 6.80 kNm |
Standard connection | T-Bolt clamp (to forkhead) | Universal clamp |
Application | T225: Primary waling beam T150: Primary/secondary waling beam S150: Secondary waling beam |